§22A-2-35. Other blasting devices.
Official statutory text
(a) The provisions governing the handling, storage, transportation and use of permissible explosives shall apply to all other blasting devices employing a heater element when used underground.
(b) Where compressed air is used for blasting, the airlines shall be grounded at the compressor and, if practical, at other low-resistant ground connections along the lines. They shall not be connected in any way to rails, waterlines or other electric return conductors and shall be adequately insulated and protected where they cross electric wires, underneath track or at places where equipment passes over or under. Steel, copper or other airlines connected therewith shall not be handled or repaired when air pressure is in the line. Shutoff valves shall be installed every thousand feet in all compressed-air blasting lines and at all points where branch lines leave the main line and blowdown valves shall not be less than fifty feet from the face and shall be around a corner.
(c) When misfires occur with any other blasting devices, they shall be handled in a safe manner and under the supervision of the mine foreman or a certified person designated by him
(b) Where compressed air is used for blasting, the airlines shall be grounded at the compressor and, if practical, at other low-resistant ground connections along the lines. They shall not be connected in any way to rails, waterlines or other electric return conductors and shall be adequately insulated and protected where they cross electric wires, underneath track or at places where equipment passes over or under. Steel, copper or other airlines connected therewith shall not be handled or repaired when air pressure is in the line. Shutoff valves shall be installed every thousand feet in all compressed-air blasting lines and at all points where branch lines leave the main line and blowdown valves shall not be less than fifty feet from the face and shall be around a corner.
(c) When misfires occur with any other blasting devices, they shall be handled in a safe manner and under the supervision of the mine foreman or a certified person designated by him
Status: in_force · Read it on the official government site
Need a lawyer in West Virginia?
Find a West Virginia lawyer
About this page: Statute text is reproduced from official government publishers via the
Open US Law dataset
(Vaquill AI, snapshot v2026.08, CC BY 4.0). Primary legislative text like this is public domain under the government-edicts doctrine
(Georgia v. Public.Resource.Org, 2020). We link every section back to its official source so you can verify it independently.